Scenario Description
Drive the needle 6 times through the silicone module. For the first three throws go from the center dot to the left three dots with the needle holder on the right side. Next place the needle in the start position and switch sides. Now drive the needle from the center to the right three dots with the needle holder held on the left side. Return the needle to the start position to finish.
Instructions
- Grab the needle from starting position.
- Position the needle in needle holder and pierce through middle and left lower point of the module.
- Position the needle in needle holder and pierce through middle and left middle point of the module.
- Position the needle in needle holder and pierce through middle and left upper point of the module.
- Swap the sides of dissector and needle holder.
- Position the needle in needle holder and pierce through middle and right upper point of the module.
- Position the needle in needle holder and pierce through middle and right middle point of the module.
- Position the needle in needle holder and pierce through middle and right lower point of the module.
Preparation
 Training module
Place the silicone dome-shaped module in the center of the Suturing module. Position the starting point for the needle above it.
  Training module position
Place the module in the training area in the middle position.
 Instruments
Prepare 5 mm instruments: dissector and needle holder.
 Instrument ports
Use the 2nd and 9th instrument ports.
 Accessories
Place 2 cm of suture material into the needle start position.
Keep your attention
Ultimately, you are the best judge of your training experience. Take a moment to reflect and ask yourself if you’ve met the criteria outlined below.
All 6 pierces must go through following points.
 Duration of training is about 15 min.